banner

Products

Home Bently Nevada

3300/20-11-01-02-00-02 BENTLY NEVADA Power Board

3300/20-11-01-02-00-02 BENTLY NEVADA  Power Board
3300/20-11-01-02-00-02 BENTLY NEVADA  Power Board

3300/20-11-01-02-00-02 BENTLY NEVADA Power Board

3300/20-11-01-02-00-02 BENTLY NEVADA  Power Board

  • Item NO.:

    3300/20-11-01-02-00-
  • Payment:

    T/T
  • Product Origin:

    USA
  • Color:

    New
  • Lead Time:

    IN STOCK

3300/20-11-01-02-00-02 BENTLY NEVADA  Power Board

These instructions are forinstallation in a hazardous environment. Forinstallation in a nonhazardous location, See "General Installation" on page 18 Forinstallation in a Class 1Div 2 environment, CSA 22.2 and ANSI/ISA-12.12.01 are the applicable standards. The equipment is compliant with the standards of EN60079-0, EN60079-11, EN60079-15 and IEC60079-0, IEC60079-11, IEC60079-15 for Zone 2. 2300 Series vibration monitoris suitable to use in a Zone 2G IIC T4 environment. The installation and maintenance of the equipment must comply with EN/IEC60079 when used in Hazardous Area Installations: For Zone 2 Installations l This device is classified as OPEN type equipment, and therefore must be used within an enclosure having a minimum ingress protection rating of IP54 according to IEC & EN 60079- 0. The interior of which is accessible only through the use of a tool. l Wiring to orfrom this device, which enters orleaves the system enclosure, must utilize wiring methods suitable for Zone 2, group IIC and T4Hazardous Locations, as appropriate forthe installation. l This EX marking of equipment: Ex nA nC [ic] IIC T4Gc and II 3G Ex nA nC [ic] IIC T4Gc. Note that use in Zone 2 is achieved using this nA nC [ic.], no longer nL. l Intrinsic safety parameters: o For Proximitor Transducer: Uo: 24VDC; Io: 46mA; Co: 200nF; Lo: 1mH o For Accelerometer/Velomitor Transducer: Uo: 24VDC; Io: 3.3mA; Co: 200nF; Lo: 1mH l Relay output: 5 amp, 30 VDC l See "Example Housing Installation" on page 64 for cable wiring in hazardous area and for the blue wiring of intrinsic safety circuit, special consideration is needed forintrinsic circuits or wiring, [see EN/IEC60079-14, clause Cables] l Please referto field wiring diagram 106M5801 for hazardous area usage.

The structure and details of the product:

 

Please make an inquiry for more models

  BENTLY NEVADA BENTLY9200-01-05-10-00

  BENTLY NEVADA 125388-01

  BENTLY NEVADA 127610-01 3500/15

  BENTLY NEVADA 128275-01

  BENTLY NEVADA 135813-01

  BENTLY NEVADA 136719-01

  BENTLY NEVADA 3300/03 3300/03-01-00

  BENTLY NEVADA 3300/05-23-00-00

  BENTLY NEVADA 3300/16 3300/0-00-00

  BENTLY NEVADA 3300/20 3300/20-0

  BENTLY NEVADA 3300/35 3300/35-2

  BENTLY NEVADA 3300/46 3300/46-46-04-02-01

  BENTLY NEVADA 3300/50 3300/50-01-01-00-00

  BENTLY NEVADA 3300/65 3300/65-1-00

  BENTLY NEVADA 3300XL 8MM

  BENTLY NEVADA 330101-00-

  BENTLY NEVADA 330101-00-28-10-02-05

  BENTLY NEVADA 330103-00-03-10-02-05

  BENTLY NEVADA 330103-00-04-10-02-05

  BENTLY NEVADA 330103-00-05-05-02-05

  BENTLY NEVADA 330103-00-05-10-02-05

  BENTLY NEVADA 330103-00-

  BENTLY NEVADA 330103-00-

  BENTLY NEVADA 330103-05-10-10-02-05

  BENTLY NEVADA 330103-10-

  BENTLY NEVADA 330104-00-04-10-02-05

  BENTLY NEVADA 330104-00-06-10-11-00

  BENTLY NEVADA 330104-00-11-10-02-05

  BENTLY NEVADA 330104-05-

  BENTLY NEVADA 330104-0

  BENTLY NEVADA 330104-0

  BENTLY NEVADA 330104-5

  BENTLY NEVADA 330105-02-12-90-02-05

  BENTLY NEVADA 330130-040-02-05

  BENTLY NEVADA 330130-045-02-05

Other best-selling products:

 

 

  • Siemens  TXI2.OPEN Controller module

    SIEMENS TXI2.OPEN Controller module

    POWER SUPPLY CONVERTER
  • B&R 0AK810.1 Input module

    B&R 0AK810.1 Input Module

      Power Supply
  • HONEYWELL TK-ZLCSR1 Power module

    HONEYWELL TK-ZLCSR1 Power Module

     

    Programmable Controller Module
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related products

330180-50-05 BENTLY Input module
330180-50-05 BENTLY Input module

The primary uses for the 3300 XL NSv Transducer System are for areas where counter bore, sideview, o...

147025-01 BENTLY Output module
147025-01 BENTLY Output module

Bently Nevada Bently Nevada P/N CA18745-XX MOD: 147025-01 7200 SERIES Proximity Senso...

837-N13 A-B  Basis unit
837-N13 A-B Basis unit

837-N13 A-B  Basis unit 

1443-KIT-DATACLTR0 A-B  analog module
1443-KIT-DATACLTR0 A-B analog module

1443-KIT-DATACLTR0 A-B  analog module

126648-01 Bently  analog module
126648-01 Bently analog module

126648-01 Bently  analog module

125840-02 Bently  Filter Modules
125840-02 Bently Filter Modules

125840-02 Bently  Filter Modules

146031-01 Bently  Analog Input Module
146031-01 Bently Analog Input Module

146031-01 Bently  Analog Input Module

190214-01 Bently  Analog Output Modules
190214-01 Bently Analog Output Modules

190214-01 Bently  Analog Output Modules

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Home

Products

whatsApp

contact