banner

Products

Home Bently Nevada

90225-23-03-05-01-02-02-03-01-02 BENTLY NEVADA Interface Module

90225-23-03-05-01-02-02-03-01-02 BENTLY NEVADA  Interface Module
90225-23-03-05-01-02-02-03-01-02 BENTLY NEVADA  Interface Module

90225-23-03-05-01-02-02-03-01-02 BENTLY NEVADA Interface Module

90225-23-03-05-01-02-02-03-01-02 BENTLY NEVADA  Interface Module

  • Item NO.:

    90225-23-03-05-01-02
  • Payment:

    T/T
  • Product Origin:

    USA
  • Color:

    New
  • Lead Time:

    IN STOCK

90225-23-03-05-01-02-02-03-01-02 BENTLY NEVADA  Interface Module

The rack provides slots for two Power Supplies and a TDI in the left-most rack positions that are reserved exclusively for these modules. The remaining 14 slots in the rack can accommodate any combination of monitor, display, relay, Keyphasor module, and communication gateway modules. All modules plug into the rack’s backplane and consist of a main module and an associated I/O module. The I/O module installs at the rear of the rack for panel-mount systems, and above the main module for bulkhead-mount systems. Standard rack depth is 349 mm (13.75 inches), while bulkhead mount rack depth is 267 mm (10.5 inches). NEMA 4 and 4X weatherproof housings are available when required for environmental protection or when purge air is used.The 3500/15 Power Supply can be ordered for ac or dc input power, providing compatibility with voltage sources worldwide. Line noise filters are standard. The 3500 Rack can operate from a single supply, or dual supplies can be used to provide redundancy for situations that cannot tolerate power interruption. Dual supplies reside in the upper and lower positions of the left-most rack slot. Redundant supplies can use separate voltage sources. For example, the primary (lower) supply can operate with 120 Vac power while the backup (upper) supply can be powered from an uninterruptible 24 Vdc source. Each supply can individually provide power to the entire rack and its modules. When redundant supplies are used, the lower supply acts as primary power for the rack while the upper supply acts as a backup, ready to instantly and automatically operate as the primary rack supply without interrupting rack functions should the primary supply fail. The 3500/15 Power Supply module has self-monitoring functions that allow it to determine if all its output voltages are within specifications. The module annunciates this via a green Supply OK LED on the power supply’s front panel.

The structure and details of the product:

 

Please make an inquiry for more models

  BENTLY NEVADA BENTLY9200-01-05-10-00

  BENTLY NEVADA 125388-01

  BENTLY NEVADA 127610-01 3500/15

  BENTLY NEVADA 128275-01

  BENTLY NEVADA 135813-01

  BENTLY NEVADA 136719-01

  BENTLY NEVADA 3300/03 3300/03-01-00

  BENTLY NEVADA 3300/05-23-00-00

  BENTLY NEVADA 3300/16 3300/0-00-00

  BENTLY NEVADA 3300/20 3300/20-0

  BENTLY NEVADA 3300/35 3300/35-2

  BENTLY NEVADA 3300/46 3300/46-46-04-02-01

  BENTLY NEVADA 3300/50 3300/50-01-01-00-00

  BENTLY NEVADA 3300/65 3300/65-1-00

  BENTLY NEVADA 3300XL 8MM

  BENTLY NEVADA 330101-00-

  BENTLY NEVADA 330101-00-28-10-02-05

  BENTLY NEVADA 330103-00-03-10-02-05

  BENTLY NEVADA 330103-00-04-10-02-05

  BENTLY NEVADA 330103-00-05-05-02-05

  BENTLY NEVADA 330103-00-05-10-02-05

  BENTLY NEVADA 330103-00-

  BENTLY NEVADA 330103-00-

  BENTLY NEVADA 330103-05-10-10-02-05

  BENTLY NEVADA 330103-10-

  BENTLY NEVADA 330104-00-04-10-02-05

  BENTLY NEVADA 330104-00-06-10-11-00

  BENTLY NEVADA 330104-00-11-10-02-05

  BENTLY NEVADA 330104-05-

  BENTLY NEVADA 330104-0

  BENTLY NEVADA 330104-0

  BENTLY NEVADA 330104-5

  BENTLY NEVADA 330105-02-12-90-02-05

  BENTLY NEVADA 330130-040-02-05

  BENTLY NEVADA 330130-045-02-05

Other best-selling products:

  • Siemens  TXI2.OPEN Controller module

    SIEMENS TXI2.OPEN Controller module

    POWER SUPPLY CONVERTER
  • B&R 0AK810.1 Input module

    B&R 0AK810.1 Input Module

      Power Supply
  • HONEYWELL TK-ZLCSR1 Power module

    HONEYWELL TK-ZLCSR1 Power Module

     

     Digital Input Module
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related products

330180-50-05 BENTLY Input module
330180-50-05 BENTLY Input module

The primary uses for the 3300 XL NSv Transducer System are for areas where counter bore, sideview, o...

147025-01 BENTLY Output module
147025-01 BENTLY Output module

Bently Nevada Bently Nevada P/N CA18745-XX MOD: 147025-01 7200 SERIES Proximity Senso...

837-N13 A-B  Basis unit
837-N13 A-B Basis unit

837-N13 A-B  Basis unit 

1443-KIT-DATACLTR0 A-B  analog module
1443-KIT-DATACLTR0 A-B analog module

1443-KIT-DATACLTR0 A-B  analog module

126648-01 Bently  analog module
126648-01 Bently analog module

126648-01 Bently  analog module

125840-02 Bently  Filter Modules
125840-02 Bently Filter Modules

125840-02 Bently  Filter Modules

146031-01 Bently  Analog Input Module
146031-01 Bently Analog Input Module

146031-01 Bently  Analog Input Module

190214-01 Bently  Analog Output Modules
190214-01 Bently Analog Output Modules

190214-01 Bently  Analog Output Modules

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Home

Products

whatsApp

contact