SAPC38RCC  ABB  Power Board

In addition to that mentioned in the above sections, the self-supervision unit (IRF) monitors the operating voltage of the relay. If a fault is detected in the operating voltages, the self-supervision unit prevents the relay from operating. In addition, the “IRF” LED of the central unit is lit, and the IRF relay resets.

The self-supervision signal output operates on the closed circuit principle as presented in the figure below. Under normal conditions, the output relay is energized and the contact gap between 8 and 10 is closed. If the auxiliary power supply fails, or an internal fault is detected, the contact gap between 8 and 10 is opened.

When the “Trip Condition” key switch is in the “Current&Light” position, and the “Current&Light” LED is lit (normal operation), the overcurrent condition level is in use. Thereby both overcurrent and light are required for tripping. • Take the overcurrent condition level into use (overcurrent and light required for tripping) by using the switches SG1/1...4 (L1, L2, L3 inputs), or SG1/1...4 (L1, L3), and SG4/1...5 (L2). When the key switch is in the “Light” position and the “Current” LED is lit, the overcurrent condition level is not in use. Thereby only light is required for tripping. This option can be used, for example, during service.

Remember when constructing applications • Do not change connections or set any switches when the supply voltage is connected to the units. • Condition monitoring of a radial sensor fiber is not possible. When commissioning a radial sensor fiber, remember to set the SG3/4 switch in position ON. • Check the switches of the ports, when adding or removing extension units. Remember that the maximum number of extension units to be linked to one port is five, that is, ten extension units at the maximum can be connected to one REA 101 relay. Check that the terminal resistor of the last extension unit of either port is switched in the ON position (SG1/1). • When the circuit-breaker failure protection is used, it should be noted that the delay of the circuit-breaker failure protection is controlled by the overcurrent signal. Should the first trip be successful and the overcurrent disappear before the delay time runs out, no delayed tripping will occur. If the overcurrent situation lasts throughout the delay time, a delayed trip signal will be delivered. The “Trip Condition” key switch can be used to activate an overcurrent signal. Then the delayed trip function always operates in a trip situation, provided the circuitbreaker failure protection is in use. • Overcurrent information between two REA 101 central units has to be transmitted either over OPTOLINK connections and the signal transfer fiber, or over the connection cable of the extension units and the REA 105 unit, but not via both at the same time.

The structure and details of the product:

Please make an inquiry for more models

  ABB TB8073BSE008538R1

  ABB SD8333BSC610066R1

  ABB TK801V0123BSC950089R3

  ABB TB8063BSE008536R1

  ABB TB8253BSE036634R1

  ABB TU833V13BSE038726R1

  ABB SD8343BSC610067R1

  ABB TB8103BSE008560R1

  ABB TK811V0503BSC950107R2

  ABB TB8423BSE022464R1

  ABB TB40A3BSE037760R1

  ABB AO845A3BSE045584R1

  ABB AO801-eA3BSE020514R2

  ABB DI801-eA3BSE020508R2

  ABB DO801-eA3BSE020510R2

  ABB DI811-eA3BSE008552R2

  ABB AI810-eA3BSE008516R2

  ABB AI830A-eA3BSE040662R2

  ABB DP840-eA3BSE028926R2

  ABB AO845A-eA3BSE045584R2

  ABB AI835A-eA3BSE051306R2

  ABB DO810-eA3BSE008510R2

  ABB TB820V2-eA3BSE013208R2

  ABB AO810V2-eA3BSE038415R2

  ABB AI820-eA3BSE008544R2

  ABB DI821-eA3BSE008550R2

  ABB AO820-eA3BSE008546R2

  ABB DO802-eA3BSE022364R2

  ABB DI810-eA3BSE008508R2

  ABB AI845-eA3BSE023675R2

  ABB AI801-eA3BSE020512R2

  ABB DI803-eA3BSE022362R2

  ABB DI802-eA3BSE022360R2

  ABB TB40A-eA3BSE037760R2

  ABB TB825-eA3BSE036634R2

  ABB PM866K023BSE050199R1

  ABB PM861AK023BSE018160R1

  ABB PM866K013BSE050198R1

  ABB PM851AK013BSE066485R1

  ABB TB8523BSC950263R1

  ABB PM864AK023BSE018164R1

  ABB PM856AK013BSE066490R1

  ABB TK850V0073BSC95019R1

  ABB SB8223BSE018172R1

  ABB PM860AK013BSE066495R1

  ABB TB8503BSC950193R1

  ABB TK851V0103BSC950262R1

  ABB TK212A3BSC630197R1

  ABB SB8213BSE018109R1

  ABB TB8513BSC950194R1

  ABB MB801V5123BSE042257R1

  ABB PM861AK01-eA3BSE018157R2

  ABB PM861AK02-eA3BSE018160R2

  ABB PM856AK01-eA3BSE066490R2

  ABB PM866K01-eA3BSE050198R2

  ABB PM851AK01-eA3BSE066485R2

  ABB PM864AK02-eA3BSE018164R2

  ABB PM860AK01-eA3BSE066495R2

  ABB PM864AK01-eA3BSE018161R2

  ABB PM866K02-eA3BSE050199R2

JUSTWELL PTE. LTD. sells new and discontinued products, and purchases such specialty products through independent channels.JUSTWELL PTE. LTD., Ltd. is not an authorized distributor, distributor, or representative of the featured products on this website. All product names/images, trademarks, brands, and logos used on this website are the property of their respective owners. Product descriptions, descriptions, or sales with these name images, trademarks, brands, and logos are for identification purposes only and do not imply any association or authorization with any rights holders.

Our main products include DCS control system spare parts, PLC system spare parts, and robot system spare parts. Our advantageous brands include Allen Bradley, Bently Nevada, ABB, HIMA, Reliance, Bender, National Instruments, Emerson Ovation, Honeywell, Siemens, Allen Bradley, ICS Triplex, FOXBORO, Schneider, GE Fanuc, Motorola, HIMA, Prosoft, and other imported industrial components. Our main products serve a wide range of electronic, metallurgical, chemical, and power plants Industries such as steel mills, rubber, cement, machinery and equipment, and construction.

Other best-selling products:

  • Siemens  TXI2.OPEN Controller module

    SIEMENS TXI2.OPEN Controller module

    POWER SUPPLY CONVERTER
  • HONEYWELL 51304453-100 I/O module

    HONEYWELL 51304453-100 I/O Module

      Power Supply
  • A-B  1769-L24ER-QB1B  Power module

    A-B 1769-L24ER-QB1B Power module

    Programmable Controller Modu
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Related products

RTU520 ABB Controller module
RTU520 ABB Controller module

Power supply 520PSD01 RTU520 product line Application, characteristics and technical data have to be...

CI867K01 ABB Power module
CI867K01 ABB Power module

It uses with ABB Advant Controller 400 series, as well as other automation systems support...

CC-U/STD ABB Controller module
CC-U/STD ABB Controller module

More than 120 configurations possible Configurable output signal response on input signal interrupti...

PFEA111-65 ABB I/O module
PFEA111-65 ABB I/O module

The information in this document is subject to change without notice and should not be construed as ...

3BSM000248-1 ABB Power module
3BSM000248-1 ABB Power module

If you wish to discard electrical and electronic equipment (EEE), in the European Union, please cont...

3BSM000249-1 ABB Processor module
3BSM000249-1 ABB Processor module

When commissioning is completed you can use the form in Appendix H, where actual commissioning data ...

1SDA053954R1 ABB Controller module
1SDA053954R1 ABB Controller module

ABB 1SDA053954R1 T2S SACE Tmax 3P 50A 480V Breaker W/Bolts (CHIP)

RTU520 ABB programmable controller module
RTU520 ABB programmable controller module

The document describes the requirements and installation steps needed to build up a full RTU500 seri...

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Home

Products

whatsApp

contact