banner

Products

Home Allen-Bradley

1771-OQ A-B Analog Output Modules

1771-OQ A-B  Analog Output Modules
1771-OQ A-B  Analog Output Modules

1771-OQ A-B Analog Output Modules

1771-OQ A-B  Analog Output Modules

  • Item NO.:

    1771-OQ
  • Payment:

    T/T
  • Product Origin:

    USA
  • Color:

    New
  • Lead Time:

    IN STOCK

1771-OQ A-B  Analog Output Modules

The POINT I/O system does not have the ability to detect an empty terminal base. Because of this, there are numerous situations in which you can potentially configure a system that is unusable or one that exercises unintended control. In an attempt to address these situations, you must observe the following rules for POINT I/O system construction and the removal and reinsertion of modules • A correct POINT I/O system does not have any empty terminal bases. • After you cycle power, the adapter does not run any I/O until the number of modules comprising the chassis equals the stored chassis size. – Because the adapter cannot detect empty terminal bases, it cannot assume any safe operation until there is a match between the number of modules indicating their presence in the chassis and what the adapter has saved in non-volatile memory. – Actual module identification (such as, electronic keying) is done when connection establishment requests are received from the controller or controllers. • A module removed under power does not disrupt operation of the other I/O modules. – When you remove a module, the adapter determines what changed. – Whenever you remove a module with an active connection from the POINT I/O system, the adapter indicates this by flashing the POINTBus Status LED red and reports a minor recoverable fault. • If more than one contiguous module is removed under power, connections to all modules in the contiguous missing module set are disallowed until all modules are replaced. Because the adapter cannot detect an empty base, it does not know the physical positioning of the modules until all the missing modules are replaced. • If a module separating two sets of contiguous missing modules is removed, the two sets merge into a single set. All the modules must be replaced before connections are permitted to any module in the set. • If modules of different types are removed and returned to the wrong locations, attempts to connect to these modules fail during verification of the electronic ID (providing that keying has not been disabled). • If modules of the same type are removed and returned to the wrong locations, they accept connections from the controller or controllers and reconfigure with the correct data once they pass their electronic keying check. • These removal and return conditions apply whether the system is under power or not. If the system is under power, the situation arises immediately. If the system is not under power, the situation arises in the next power cycle.

The structure and details of the product:

 

Please make an inquiry for more models

  AB 1756-LSP

  AB 1756-LSP/B

  AB 1756-M02AE

  AB 1756-M02AS

  AB 1756-M03SE

  AB 1756-M08SE

  AB 1756-M1

  AB 1756-M16S

  AB 1756-M16SE

  AB 1756-N2

  AB 1756-OA16

  AB 1756-OA16I

  AB 1756-OB16D

  AB 1756-OB16E

  AB 1756-OB16I

  AB 1756-OB16I/A

  AB 1756-OB16IEF

  AB 1756-OB16IS

  AB 1756-OB32

  AB 1756-OB32/A

  AB 1756-OB8

  AB 1756-OF4

  AB 1756-OF41794-ADN

  AB 1756-OF6CI

  AB 1756-OF6VI

  AB 1756-OF8

  AB 1756-OF8/A

  AB 1756-OF81

  AB 1756-OG16

  AB 1756-OH8I

  AB 1756-ON8

  AB 1756-OV16E

  AB 1756-OV32E

  AB 1756-OW16I

  AB 1756-OW16I/A

  AB 1756-OX8I

  AB 1756-PA72

  AB 1756-PA72/B

  AB 1756-PA72/C

  AB 1756-PA75

  AB 1756-PA75/A

  AB 1756-PA75/B

  AB 1756-PA75R

  AB 1756-PAR2

  AB 1756-PB72

  AB 1756-PB75

  AB 1756-PB75R

  AB 1756-PBR2

  AB 1756-PC75

  AB 1756-PLS

  AB 1756-PSCA2/A

  AB 1756-RM

  AB 1756-RM2

  AB 1756-RM2/A

  AB 1756SC-CTR8

  AB 1756-SRM/B

  AB 1756-TBCH

  AB 1756-TBNH

  AB 1756-TBS6H

Other best-selling products:

 

  • Siemens  TXI2.OPEN Controller module

    SIEMENS TXI2.OPEN Controller module

    POWER SUPPLY CONVERTER
  • B&R 0AK810.1 Input module

    B&R 0AK810.1 Input Module

      Power Supply
  • HONEYWELL TK-ZLCSR1 Power module

    HONEYWELL TK-ZLCSR1 Power Module

    Programmable Controller Module
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related products

2090-SCEP-1 A-B Power module
2090-SCEP-1 A-B Power module

Rockwell Automation announces that as of December 31, 2025, the Kinetix 0.1-0.1m Fiber Optic Ca...

800T-XD2P A-B Controller module
800T-XD2P A-B Controller module

Rockwell Automation announces that as of December 31, 2019, the 30mm Contact Block 1-NC 800T PB...

1606-XLS240E A-B Processor module
1606-XLS240E A-B Processor module

A-B 1606-XLS240E Processor module 24V,10A Single Phase Input Those responsible for the application a...

PNOZX3 A-B Controller module
PNOZX3 A-B Controller module

This document is the original document. All rights to this documentation are reserved by Pilz GmbH &...

2198-DB42-F A-B Programmable controller
2198-DB42-F A-B Programmable controller

Representative Photo Only (actual product may vary based on configuration selections)

1606-XLS480E A-B Central control module
1606-XLS480E A-B Central control module

Power Supply, 480 W, 24V DC, No Special Function, Performance Family, Global Input Voltage This prod...

2090-XNSM-M A-B Input module
2090-XNSM-M A-B Input module

Rockwell Automation announces that as of December 31, 2025, the Kinetix Safe Off Header Connect...

1747-M11 A-B Output module
1747-M11 A-B Output module

Troubleshooting and Product Information for 1747-M11 Download product information, troubleshooting g...

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Home

Products

whatsApp

contact