banner

Products

Home Allen-Bradley

2198-P031 A-B Analog Input Module

2198-P031 A-B  Analog Input Module
2198-P031 A-B  Analog Input Module

2198-P031 A-B Analog Input Module

2198-P031 A-B  Analog Input Module

  • Item NO.:

    2198-P031
  • Payment:

    T/T
  • Product Origin:

    USA
  • Color:

    New
  • Lead Time:

    IN STOCK

2198-P031 A-B  Analog Input Module

Power Cable Types Acceptable for 200…600 Volt Installations Various cable types are acceptable for drive installations. For many installations, unshielded cable is adequate, provided it can be separated from sensitive circuits. As an approximate guide, allow a spacing of 0.3 meters (1 foot) for every 10 meters (32.8 feet) of length. In all cases, long parallel runs must be avoided. Do not use cable with an insulation thickness less than or equal to 15 mils (0.4mm/0.015 in.). Use Copper wire only. Wire gauge requirements and recommendations are based on 75 °C (167 °F). Do not reduce wire gauge when using higher temperature wire. See table below.

THHN, THWN or similar wire is acceptable for drive installation in dry environments provided adequate free air space and/or conduit fill rates limits are provided. Do not use THHN or similarly coated wire in wet areas. Any wire that is chosen must have a minimum insulation thickness of 15 mils and should not have large variations in insulation concentricity. Shielded/Armored Cable Shielded cable contains all general benefits of multi-conductor cable with the added benefit of a copper braided shield that can contain much of the noise that is generated by a typical AC drive. Strong consideration for shielded cable should be given in installations with sensitive equipment such as weigh scales, capacitive proximity switches and other devices that may be affected by electrical noise in the distribution system. Applications with large numbers of drives in a similar location, imposed EMC regulations or a high degree of communications/ networking are also good candidates for shielded cable. Shielded cable may also help reduce shaft voltage and induced bearing currents for some applications. In addition, the increased impedance of shielded cable may help extend the distance that the motor can be located from the drive without the addition of motor protective devices such as terminator networks. Consideration should be given to all general specifications that are dictated by the environment of the installation, including temperature, flexibility, moisture characteristics and chemical resistance. In addition, a braided shield should be included and be specified by the cable manufacturer as having coverage of at least 75%. An additional foil shield can greatly improve noise containment. A good example of recommended cable is Belden 295xx (xx determines gauge). This cable has four (4) XLPE insulated conductors with a 100% coverage foil and an 85% coverage copper braided shield (with drain wire) surrounded by a PVC jacket. Other types of shielded cable are available, but the selection of these types may limit the allowable cable length. Particularly, some of the newer cables twist four conductors of THHN wire and wrap them tightly with a foil shield. This construction can greatly increase the cable charging current required and reduce the overall drive performance. Unless specified in the individual distance tables as tested with the drive, these cables are not recommended and their performance against the lead length limits supplied is not known.

The structure and details of the product:

 

Please make an inquiry for more models

  AB 1756-LSP

  AB 1756-LSP/B

  AB 1756-M02AE

  AB 1756-M02AS

  AB 1756-M03SE

  AB 1756-M08SE

  AB 1756-M1

  AB 1756-M16S

  AB 1756-M16SE

  AB 1756-N2

  AB 1756-OA16

  AB 1756-OA16I

  AB 1756-OB16D

  AB 1756-OB16E

  AB 1756-OB16I

  AB 1756-OB16I/A

  AB 1756-OB16IEF

  AB 1756-OB16IS

  AB 1756-OB32

  AB 1756-OB32/A

  AB 1756-OB8

  AB 1756-OF4

  AB 1756-OF41794-ADN

  AB 1756-OF6CI

  AB 1756-OF6VI

  AB 1756-OF8

  AB 1756-OF8/A

  AB 1756-OF81

  AB 1756-OG16

  AB 1756-OH8I

  AB 1756-ON8

  AB 1756-OV16E

  AB 1756-OV32E

  AB 1756-OW16I

  AB 1756-OW16I/A

  AB 1756-OX8I

  AB 1756-PA72

  AB 1756-PA72/B

  AB 1756-PA72/C

  AB 1756-PA75

  AB 1756-PA75/A

  AB 1756-PA75/B

  AB 1756-PA75R

  AB 1756-PAR2

  AB 1756-PB72

  AB 1756-PB75

  AB 1756-PB75R

  AB 1756-PBR2

  AB 1756-PC75

  AB 1756-PLS

  AB 1756-PSCA2/A

  AB 1756-RM

  AB 1756-RM2

  AB 1756-RM2/A

  AB 1756SC-CTR8

  AB 1756-SRM/B

  AB 1756-TBCH

  AB 1756-TBNH

  AB 1756-TBS6H

Other best-selling products:

 

  • Siemens  TXI2.OPEN Controller module

    SIEMENS TXI2.OPEN Controller module

    POWER SUPPLY CONVERTER
  • B&R 0AK810.1 Input module

    B&R 0AK810.1 Input Module

      Power Supply
  • HONEYWELL TK-ZLCSR1 Power module

    HONEYWELL TK-ZLCSR1 Power Module

    Programmable Controller Module
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related products

2090-SCEP-1 A-B Power module
2090-SCEP-1 A-B Power module

Rockwell Automation announces that as of December 31, 2025, the Kinetix 0.1-0.1m Fiber Optic Ca...

800T-XD2P A-B Controller module
800T-XD2P A-B Controller module

Rockwell Automation announces that as of December 31, 2019, the 30mm Contact Block 1-NC 800T PB...

1606-XLS240E A-B Processor module
1606-XLS240E A-B Processor module

A-B 1606-XLS240E Processor module 24V,10A Single Phase Input Those responsible for the application a...

PNOZX3 A-B Controller module
PNOZX3 A-B Controller module

This document is the original document. All rights to this documentation are reserved by Pilz GmbH &...

2198-DB42-F A-B Programmable controller
2198-DB42-F A-B Programmable controller

Representative Photo Only (actual product may vary based on configuration selections)

1606-XLS480E A-B Central control module
1606-XLS480E A-B Central control module

Power Supply, 480 W, 24V DC, No Special Function, Performance Family, Global Input Voltage This prod...

2090-XNSM-M A-B Input module
2090-XNSM-M A-B Input module

Rockwell Automation announces that as of December 31, 2025, the Kinetix Safe Off Header Connect...

1747-M11 A-B Output module
1747-M11 A-B Output module

Troubleshooting and Product Information for 1747-M11 Download product information, troubleshooting g...

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Home

Products

whatsApp

contact