
440L-AM1251350 A-B Central Control Unit
Item NO.:
440L-AM1251350Payment:
T/TProduct Origin:
USAColor:
NewLead Time:
IN STOCK440L-AM1251350 A-B Central Control Unit
Disconnecting MOVs To help prevent drive damage, disconnect the MOVs connected to ground if the drive is installed on an ungrounded distribution system (IT mains) where the line-to-ground voltages on any phase could exceed 125% of the nominal line-to-line voltage. To disconnect these devices, remove the jumper that is shown in the following diagrams. 1. Turn the screw counterclockwise to loosen. 2. Pull the jumper completely out of the drive chassis. 3. Tighten the screw to keep it in place
Input Power Conditioning The drive is suitable for direct connection to input power within the rated voltage of the drive. See Input Power Conditions on page 20. Listed in the Input Power Conditions table below are certain input power conditions that can cause component damage or reduction in product life. If any of these conditions exist, install one of the devices that are listed under the heading Corrective Action on the line side of the drive.
General Grounding Requirements The drive safety ground - (PE) must be connected to the system ground. Ground impedance must conform to the requirements of national and local industrial safety regulations and/or electrical codes. Check the integrity of all ground connections periodically.
Shield Termination - SHLD Either of the safety ground terminals that are on the power terminal block provide a grounding point for the motor cable shield. The motor cable shield connected to one of these terminals (drive end) should also be connected to the motor frame (motor end). Use a shield terminating or EMI clamp to connect the shield to the safety ground terminal. The earthing plate or conduit box option may be used with a cable clamp for a grounding point for the cable shield. When a shielded cable is used for control and signal wiring, ground the shield at the source end only, not at the drive end. RFI Filter Grounding Using a drive with a filter can result in relatively high ground leakage currents. Therefore, the filter must only be used in installations with grounded AC supply systems and be permanently installed and solidly grounded (bonded) to the building power distribution ground. Verify that the incoming supply neutral is solidly connected (bonded) to the same building power distribution ground. Grounding must not rely on flexible cables and should exclude any form of plug or socket that permits inadvertent disconnection. Some local codes may require redundant ground connections. The integrity of all connections should be periodically checked.
The structure and details of the product:
Please make an inquiry for more models
ABB TB8073BSE008538R1
ABB SD8333BSC610066R1
ABB TK801V0123BSC950089R3
ABB TB8063BSE008536R1
ABB TB8253BSE036634R1
ABB TU833V13BSE038726R1
ABB SD8343BSC610067R1
ABB TB8103BSE008560R1
ABB TK811V0503BSC950107R2
ABB TB8423BSE022464R1
ABB TB40A3BSE037760R1
ABB AO845A3BSE045584R1
ABB AO801-eA3BSE020514R2
ABB DI801-eA3BSE020508R2
ABB DO801-eA3BSE020510R2
ABB DI811-eA3BSE008552R2
ABB AI810-eA3BSE008516R2
ABB AI830A-eA3BSE040662R2
ABB DP840-eA3BSE028926R2
ABB AO845A-eA3BSE045584R2
ABB AI835A-eA3BSE051306R2
ABB DO810-eA3BSE008510R2
ABB TB820V2-eA3BSE013208R2
ABB AO810V2-eA3BSE038415R2
ABB AI820-eA3BSE008544R2
ABB DI821-eA3BSE008550R2
ABB AO820-eA3BSE008546R2
ABB DO802-eA3BSE022364R2
ABB DI810-eA3BSE008508R2
ABB AI845-eA3BSE023675R2
ABB AI801-eA3BSE020512R2
ABB DI803-eA3BSE022362R2
ABB DI802-eA3BSE022360R2
ABB TB40A-eA3BSE037760R2
ABB TB825-eA3BSE036634R2
ABB PM866K023BSE050199R1
ABB PM861AK023BSE018160R1
ABB PM866K013BSE050198R1
ABB PM851AK013BSE066485R1
ABB TB8523BSC950263R1
ABB PM864AK023BSE018164R1
ABB PM856AK013BSE066490R1
ABB TK850V0073BSC95019R1
ABB SB8223BSE018172R1
ABB PM860AK013BSE066495R1
ABB TB8503BSC950193R1
ABB TK851V0103BSC950262R1
ABB TK212A3BSC630197R1
ABB SB8213BSE018109R1
ABB TB8513BSC950194R1
ABB MB801V5123BSE042257R1
ABB PM861AK01-eA3BSE018157R2
ABB PM861AK02-eA3BSE018160R2
ABB PM856AK01-eA3BSE066490R2
ABB PM866K01-eA3BSE050198R2
ABB PM851AK01-eA3BSE066485R2
ABB PM864AK02-eA3BSE018164R2
ABB PM860AK01-eA3BSE066495R2
ABB PM864AK01-eA3BSE018161R2
ABB PM866K02-eA3BSE050199R2
JUSTWELL PTE. LTD. sells new and discontinued products, and purchases such specialty products through independent channels. Xiamen Rongfeng Electrical Equipment Co., Ltd. is not an authorized distributor, distributor, or representative of the featured products on this website. All product names/images, trademarks, brands, and logos used on this website are the property of their respective owners. Product descriptions, descriptions, or sales with these name images, trademarks, brands, and logos are for identification purposes only and do not imply any association or authorization with any rights holders.
Our main products include DCS control system spare parts, PLC system spare parts, and robot system spare parts. Our advantageous brands include Allen Bradley, Bently Nevada, ABB, HIMA, Reliance, Bender, National Instruments, Emerson Ovation, Honeywell, Siemens, Allen Bradley, ICS Triplex, FOXBORO, Schneider, GE Fanuc, Motorola, HIMA, Prosoft, and other imported industrial components. Our main products serve a wide range of electronic, metallurgical, chemical, and power plants Industries such as steel mills, rubber, cement, machinery and equipment, and construction.
Other best-selling products:


