banner

Products

Home Allen-Bradley

6177R-RMSNO A-B Communication Interface

6177R-RMSNO A-B  Communication Interface
6177R-RMSNO A-B  Communication Interface

6177R-RMSNO A-B Communication Interface

6177R-RMSNO A-B  Communication Interface

  • Item NO.:

    6177R-RMSNO
  • Payment:

    T/T
  • Product Origin:

    USA
  • Color:

    New
  • Lead Time:

    IN STOCK

6177R-RMSNO A-B  Communication Interface

To set the control to a given differential, turn adjustment screw "B" clockwise approximately 12 turns. Apply the difference pressure to "trip" the control as in the "Difference Pressure Setting" paragraph. Lower and maintain this pressure at the desired differential. Turn the adjustment screw "B" counterclockwise until the switch just "resets". For the 2 - circuit snap switch contacts 1-2 will close. For the 4 - circuit snap switch contacts 1-2 & 5-6 will close. Repeat these steps between "trip" and "reset" several times to insure proper setting. The adjustment screw "B" should never extend above the base of the enclosure. The setting procedure is now complete. Connect the top bellows, lower pressure, into the system. The control will operate as a difference pressure control with the differential as set per instructions. After the desired settings have been accomplished and the installation complete, mount the cover and tighten the four cover screws 6-8 in.-lbs to insure a good seal between cover and base. Operating variables in a system may cause changing pressure requirements. It is recommended that a periodic inspection of the gauge pressure be made and the pressure control adjusted to compensate when necessary for these changes.

SETTING CONTROL - Unless otherwise specified, controls shipped from the factory are set at the maximum operating difference pressure and minimum differential as specified on the nameplate. This would position the difference pressure adjusting bushing "A" approximately one inch from the bottom of the enclosure. Use a pressure gauge to make the following adjustments: DIFFERENCE PRESSURE SETTING: The difference pressure adjustment sets the control to "trip" the contacts at the desired difference in pressure between the two bellows as required for the application. With no pressure (open to atmosphere) applied to the top bellows, apply a constant pressure to the bottom bellows equal to the desired difference in pressure at which the contacts are to "trip" during operation of the system. Insert a 1/8" diameter rod into a hole in the adjusting bushing "A" and turn bushing to the left. Continue to turn bushing until the mechanism "trips", circuit 1-2 will open. At this point, the difference pressure is set at the pressure which is being applied to the bottom bellows

The structure and details of the product:

 

Please make an inquiry for more models

  AB 1756-LSP

  AB 1756-LSP/B

  AB 1756-M02AE

  AB 1756-M02AS

  AB 1756-M03SE

  AB 1756-M08SE

  AB 1756-M1

  AB 1756-M16S

  AB 1756-M16SE

  AB 1756-N2

  AB 1756-OA16

  AB 1756-OA16I

  AB 1756-OB16D

  AB 1756-OB16E

  AB 1756-OB16I

  AB 1756-OB16I/A

  AB 1756-OB16IEF

  AB 1756-OB16IS

  AB 1756-OB32

  AB 1756-OB32/A

  AB 1756-OB8

  AB 1756-OF4

  AB 1756-OF41794-ADN

  AB 1756-OF6CI

  AB 1756-OF6VI

  AB 1756-OF8

  AB 1756-OF8/A

  AB 1756-OF81

  AB 1756-OG16

  AB 1756-OH8I

  AB 1756-ON8

  AB 1756-OV16E

  AB 1756-OV32E

  AB 1756-OW16I

  AB 1756-OW16I/A

  AB 1756-OX8I

  AB 1756-PA72

  AB 1756-PA72/B

  AB 1756-PA72/C

  AB 1756-PA75

  AB 1756-PA75/A

  AB 1756-PA75/B

  AB 1756-PA75R

  AB 1756-PAR2

  AB 1756-PB72

  AB 1756-PB75

  AB 1756-PB75R

  AB 1756-PBR2

  AB 1756-PC75

  AB 1756-PLS

  AB 1756-PSCA2/A

  AB 1756-RM

  AB 1756-RM2

  AB 1756-RM2/A

  AB 1756SC-CTR8

  AB 1756-SRM/B

  AB 1756-TBCH

  AB 1756-TBNH

  AB 1756-TBS6H

Other best-selling products:

 

  • Siemens  TXI2.OPEN Controller module

    SIEMENS TXI2.OPEN Controller module

    POWER SUPPLY CONVERTER
  • B&R 0AK810.1 Input module

    B&R 0AK810.1 Input Module

      Power Supply
  • HONEYWELL TK-ZLCSR1 Power module

    HONEYWELL TK-ZLCSR1 Power Module

    Programmable Controller Module
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related products

2090-SCEP-1 A-B Power module
2090-SCEP-1 A-B Power module

Rockwell Automation announces that as of December 31, 2025, the Kinetix 0.1-0.1m Fiber Optic Ca...

800T-XD2P A-B Controller module
800T-XD2P A-B Controller module

Rockwell Automation announces that as of December 31, 2019, the 30mm Contact Block 1-NC 800T PB...

1606-XLS240E A-B Processor module
1606-XLS240E A-B Processor module

A-B 1606-XLS240E Processor module 24V,10A Single Phase Input Those responsible for the application a...

PNOZX3 A-B Controller module
PNOZX3 A-B Controller module

This document is the original document. All rights to this documentation are reserved by Pilz GmbH &...

2198-DB42-F A-B Programmable controller
2198-DB42-F A-B Programmable controller

Representative Photo Only (actual product may vary based on configuration selections)

1606-XLS480E A-B Central control module
1606-XLS480E A-B Central control module

Power Supply, 480 W, 24V DC, No Special Function, Performance Family, Global Input Voltage This prod...

2090-XNSM-M A-B Input module
2090-XNSM-M A-B Input module

Rockwell Automation announces that as of December 31, 2025, the Kinetix Safe Off Header Connect...

1747-M11 A-B Output module
1747-M11 A-B Output module

Troubleshooting and Product Information for 1747-M11 Download product information, troubleshooting g...

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Home

Products

whatsApp

contact