
808-D962844 A-B analog module
Item NO.:
808-D962844Payment:
T/TProduct Origin:
USAColor:
NewLead Time:
IN STOCK808-D962844 A-B analog module
Bulletin 1492-SP versus Conventional Breakers The 1492-SP line features the unique ability to achieve short-circuit interruptions far more effectively than conventional breakers. In conventional circuit breakers, the short-circuit interruption time required is approximately one or two half cycles of an AC sine wave. When the contacts open, the resulting arc continues to burn until the current level passes through zero. The arc may reignite because of the insufficient width of the contact gap. The current that flows until the arc is extinguished produces a heating effect proportional to the I2 t value (let-through-energy) of the fault current. The 1492-SP device is designed to substantially reduce the amount of letthrough-current and the resulting let-through-energy that can damage protected components. The 1492-SP has the ability to interrupt short-circuit current within the first half cycle of the fault.
Limiting let-through-energy will protect against the harmful effects of overcurrent and is focused primarily on avoiding: • excessive heat and • mechanical damage. Both of these factors are proportional to the square of the current. Thermal energy is proportional to the square of the RMS value and magnetic forces are proportional to the square of the peak value. The most effective way to provide protection is to substantially limit let-through-energy. This provides the following advantages: • Far less damage at the location of the short circuit. • Fast electric separation of a faulty unit from the system; in particular, power supplies connected in parallel that are switched off when the voltage of the power bus drops below a certain level. • Far less wear on the miniature circuit breaker itself, which means more safe interruptions. • Better protection of all components in the short circuit path. • Far wider range of selective action when used with an upstream protective device; there are no nuisance shut downs from feeder line interruptions, causing a blackout in all connected branches.
The structure and details of the product:
Please make an inquiry for more models
AB 1756-LSP
AB 1756-LSP/B
AB 1756-M02AE
AB 1756-M02AS
AB 1756-M03SE
AB 1756-M08SE
AB 1756-M1
AB 1756-M16S
AB 1756-M16SE
AB 1756-N2
AB 1756-OA16
AB 1756-OA16I
AB 1756-OB16D
AB 1756-OB16E
AB 1756-OB16I
AB 1756-OB16I/A
AB 1756-OB16IEF
AB 1756-OB16IS
AB 1756-OB32
AB 1756-OB32/A
AB 1756-OB8
AB 1756-OF4
AB 1756-OF41794-ADN
AB 1756-OF6CI
AB 1756-OF6VI
AB 1756-OF8
AB 1756-OF8/A
AB 1756-OF81
AB 1756-OG16
AB 1756-OH8I
AB 1756-ON8
AB 1756-OV16E
AB 1756-OV32E
AB 1756-OW16I
AB 1756-OW16I/A
AB 1756-OX8I
AB 1756-PA72
AB 1756-PA72/B
AB 1756-PA72/C
AB 1756-PA75
AB 1756-PA75/A
AB 1756-PA75/B
AB 1756-PA75R
AB 1756-PAR2
AB 1756-PB72
AB 1756-PB75
AB 1756-PB75R
AB 1756-PBR2
AB 1756-PC75
AB 1756-PLS
AB 1756-PSCA2/A
AB 1756-RM
AB 1756-RM2
AB 1756-RM2/A
AB 1756SC-CTR8
AB 1756-SRM/B
AB 1756-TBCH
AB 1756-TBNH
AB 1756-TBS6H
Other best-selling products:


