
SP-163182 A-B Control Unit
Item NO.:
SP-163182Payment:
T/TProduct Origin:
USAColor:
NewLead Time:
IN STOCKSP-163182 A-B Control Unit
Program files contain controller information, the main ladder program, interrupt subroutines, and any subroutine programs. These files are: • System Program (file 0) - This file contains various system related information and user–programmed information such as processor type, I/O configuration, processor file name, and password. • Reserved (file 1) - This file is reserved. • Main Ladder Program (file 2) - This file contains user–programmed instructions defining how the controller is to operate. • User Error Fault Routine (file 3) - This file is executed when a recoverable fault occurs. • High–Speed Counter Interrupt (file 4) - This file is executed when an HSC interrupt occurs. It can also be used for a subroutine ladder program. • Selectable Timed Interrupt (file 5) - This file is executed when an STI occurs. It can also be used for a subroutine ladder program. • Subroutine Ladder Program (files 6 - 15) - These are used according to subroutine instructions residing in the main ladder program file or other subroutine files.
Data files contain the status information associated with external I/O and all other instructions you use in your main and subroutine ladder program files. In addition, these files store information concerning processor operation. You can also use the files to store “recipes” and look–up tables if needed. These files are organized by the type of data they contain. The data file types are: • Output (file 0) - This file stores the state of the output terminals for the controller. • Input (file 1) - This file stores the status of the input terminals for the controller. • Status (file 2) - This file stores controller operation information. This file is useful for troubleshooting controller and program operation. • Bit (file 3) - This file is used for internal relay logic storage. • Timer (file 4) - This file stores the timer accumulator and preset values and status bits. • Counter (file 5) - This file stores the counter accumulator and preset values and the status bits. • Control (file 6) - This file stores the length, pointer position, and status bits for specific instructions such as shift registers and sequencers. • Integer (file 7) - This file is used to store numeric values or bit information.
The structure and details of the product:
Please make an inquiry for more models
AB 1756-LSP
AB 1756-LSP/B
AB 1756-M02AE
AB 1756-M02AS
AB 1756-M03SE
AB 1756-M08SE
AB 1756-M1
AB 1756-M16S
AB 1756-M16SE
AB 1756-N2
AB 1756-OA16
AB 1756-OA16I
AB 1756-OB16D
AB 1756-OB16E
AB 1756-OB16I
AB 1756-OB16I/A
AB 1756-OB16IEF
AB 1756-OB16IS
AB 1756-OB32
AB 1756-OB32/A
AB 1756-OB8
AB 1756-OF4
AB 1756-OF41794-ADN
AB 1756-OF6CI
AB 1756-OF6VI
AB 1756-OF8
AB 1756-OF8/A
AB 1756-OF81
AB 1756-OG16
AB 1756-OH8I
AB 1756-ON8
AB 1756-OV16E
AB 1756-OV32E
AB 1756-OW16I
AB 1756-OW16I/A
AB 1756-OX8I
AB 1756-PA72
AB 1756-PA72/B
AB 1756-PA72/C
AB 1756-PA75
AB 1756-PA75/A
AB 1756-PA75/B
AB 1756-PA75R
AB 1756-PAR2
AB 1756-PB72
AB 1756-PB75
AB 1756-PB75R
AB 1756-PBR2
AB 1756-PC75
AB 1756-PLS
AB 1756-PSCA2/A
AB 1756-RM
AB 1756-RM2
AB 1756-RM2/A
AB 1756SC-CTR8
AB 1756-SRM/B
AB 1756-TBCH
AB 1756-TBNH
AB 1756-TBS6H
Other best-selling products:


